On Sale!

OCULUS Pentacam HR Corneal Tomographer

Original price was: $15,600.00.Current price is: $8,150.00.

The OCULUS Pentacam HR Corneal Tomographer is an advanced, non-contact anterior segment imaging system that utilizes high-resolution rotating Scheimpflug technology to provide precise three-dimensional corneal tomography. Designed for ophthalmologists, refractive surgeons

Delivery and return
Delivery and return
Shipping Information
Shipping Information
Composition and care
Composition and care

Description

OCULUS Pentacam HR Corneal Tomographer

Advanced Scheimpflug Imaging System for Comprehensive Anterior Eye Analysis

The OCULUS Pentacam HR Corneal Tomographer is a premium diagnostic imaging system designed to provide highly accurate three-dimensional analysis of the anterior segment of the eye. Utilizing a rotating high-resolution Scheimpflug camera, the Pentacam HR captures thousands of precise elevation points within seconds, delivering comprehensive information about the cornea, anterior chamber, crystalline lens, and surrounding ocular structures.

Widely trusted by ophthalmologists, refractive surgeons, corneal specialists, cataract surgeons, and academic institutions worldwide, the Pentacam HR supports modern eye care by offering objective diagnostic data for screening, treatment planning, surgical evaluation, and long-term patient monitoring.

Unlike conventional corneal topographers that analyze only the anterior corneal surface, the Pentacam HR generates a complete three-dimensional model of the anterior eye segment. This enables clinicians to detect subtle corneal abnormalities, evaluate corneal biomechanics indirectly through tomography, assess anterior chamber geometry, calculate intraocular lens (IOL) power, and identify patients at risk for postoperative complications.

Its combination of high-speed imaging, advanced analytical software, automated measurement protocols, and exceptional repeatability has made the Pentacam HR one of the world’s most respected anterior segment imaging systems.

Why Choose the OCULUS Pentacam HR?

Selecting an advanced corneal tomographer is essential for accurate diagnosis and successful refractive or cataract surgery outcomes. The Pentacam HR provides clinicians with an extensive range of diagnostic parameters within a single examination.

Major advantages include:

  • High-resolution rotating Scheimpflug imaging
  • Non-contact examination
  • Rapid image acquisition
  • Three-dimensional anterior segment reconstruction
  • Complete corneal tomography
  • Corneal elevation analysis
  • Pachymetry mapping
  • Anterior chamber assessment
  • Lens densitometry
  • Keratoconus screening
  • Cataract analysis
  • IOL calculation support
  • Dry eye assessment compatibility
  • Excellent repeatability
  • Comprehensive diagnostic software
  • Easy workflow integration
  • Minimal operator dependency
What is the OCULUS Pentacam HR?

The OCULUS Pentacam HR is a high-resolution anterior segment tomographer that employs a rotating Scheimpflug camera combined with a monochromatic blue LED light source to acquire multiple cross-sectional images of the eye.

During a single scan, the camera rotates around the optical axis while capturing numerous slit images from different angles. These images are automatically reconstructed into an accurate three-dimensional model of the anterior eye.

This imaging technology enables simultaneous measurement of:

  • Anterior corneal surface
  • Posterior corneal surface
  • Total corneal thickness
  • Corneal elevation
  • Corneal curvature
  • Corneal volume
  • Anterior chamber depth
  • Anterior chamber angle
  • Anterior chamber volume
  • Lens position
  • Lens density
  • Pupil diameter
High-Resolution Scheimpflug Technology
Advanced Rotating Camera System

At the heart of the Pentacam HR is an ultra-high-resolution rotating Scheimpflug camera.

The camera rotates 360 degrees around the optical axis while capturing multiple slit images across the entire anterior segment.

This innovative approach provides:

  • Precise optical sectioning
  • Excellent depth of focus
  • Minimal distortion
  • High spatial resolution
  • Accurate elevation measurements
  • Superior repeatability
  • Complete three-dimensional reconstruction
Blue LED Illumination

The Pentacam HR utilizes a monochromatic blue LED light source that provides:

  • Stable illumination
  • Reduced heat generation
  • Long operating life
  • Excellent image contrast
  • Uniform image quality
  • Reliable calibration
Three-Dimensional Reconstruction

Unlike traditional topographers, the Pentacam HR reconstructs the entire anterior eye segment in three dimensions.

The reconstructed model includes:

  • Cornea
  • Iris
  • Anterior chamber
  • Crystalline lens
  • Corneal thickness profile
  • Elevation maps
  • Chamber geometry

Key Features

High-Speed Image Acquisition

The Pentacam HR performs image acquisition within only a few seconds, minimizing motion artifacts and improving examination efficiency.

Fast scanning benefits include:

  • Improved patient comfort
  • Reduced blinking artifacts
  • Better fixation
  • High reproducibility
  • Efficient clinical workflow
Fully Automatic Examination

Automated alignment and acquisition simplify operation.

Benefits include:

  • Reduced operator dependency
  • Consistent measurements
  • Faster patient throughput
  • Simplified staff training
  • Reliable results
Non-Contact Examination

No contact with the eye is required.

Advantages include:

  • No anesthesia required
  • Greater patient comfort
  • Reduced infection risk
  • Safe postoperative follow-up
  • Suitable for routine screening
Comprehensive Corneal Analysis

The Pentacam HR evaluates virtually every important corneal parameter, including:

  • Anterior elevation
  • Posterior elevation
  • Total corneal power
  • Pachymetry
  • Keratometry
  • Corneal volume
  • Corneal curvature
  • Corneal asymmetry
  • Astigmatism
  • Corneal irregularities

Clinical Benefits

Early Keratoconus Detection

One of the strongest clinical advantages of the Pentacam HR is its ability to detect early ectatic disease before clinical signs become apparent.

The software evaluates:

  • Posterior elevation changes
  • Pachymetric progression
  • Corneal asymmetry
  • Belin/Ambrosio Enhanced Ectasia Display
  • Corneal thickness distribution
  • Elevation progression
Refractive Surgery Planning

The Pentacam HR is widely used before:

  • LASIK
  • PRK
  • SMILE
  • Phakic IOL implantation
  • Corneal Cross-Linking (CXL)
Cataract Surgery Optimization

For cataract procedures, the Pentacam HR supports:

  • IOL power calculation
  • Corneal power measurement
  • Posterior corneal astigmatism evaluation
  • Total corneal refractive power
  • Lens densitometry
  • Surgical planning
Corneal Disease Management

Clinicians can monitor diseases such as:

  • Keratoconus
  • Pellucid marginal degeneration
  • Corneal edema
  • Corneal ectasia
  • Post-LASIK ectasia
  • Corneal scars
  • Corneal transplantation follow-up
Software included:

Belin Ambrosio
Holladay
Catarata
Refractiva
Contact Lens Fitting
PNS (inside the cataract module already)
(Pentacam Nucleus Staging- how much Cataract is visible)

Technical Specifications
Category Specification
Product Name OCULUS Pentacam HR Corneal Tomographer
Manufacturer OCULUS Optikgeräte GmbH
Product Type Anterior Segment Tomographer
Technology Rotating Scheimpflug Imaging System
Imaging Method Three-dimensional anterior segment tomography
Camera Type High-Resolution Rotating Scheimpflug Camera
Measurement Method Non-contact optical imaging
Operating Principle Rotating slit illumination with Scheimpflug camera acquisition
Primary Clinical Application Corneal tomography, anterior segment imaging, cataract planning, refractive surgery planning
Patient Contact None (Non-contact examination)
Measurement Mode Automatic
Alignment Automatic with live image guidance
Fixation System Internal fixation target
Image Reconstruction Automatic 3D reconstruction
Software Processing Fully automatic
Image Analysis Real-time
Patient Position Sitting
Acquisition Type Single scan
Measurement Duration Few seconds per scan
Clinical Workflow Fully digital
Optical System Specifications
Parameter Specification
Imaging Principle Scheimpflug Photography
Camera Rotation 360° rotational imaging
Illumination Monochromatic Blue LED
Optical Section Imaging Yes
Three-Dimensional Imaging Yes
Elevation Measurement Yes
Curvature Measurement Yes
Pachymetry Measurement Yes
Tomography Yes
Lens Imaging Yes
Anterior Chamber Imaging Yes
Corneal Imaging Complete
Iris Imaging Included
Lens Densitometry Supported
Optical Calibration Factory calibrated
Automatic Calibration Check Yes
Imaging Specifications
Feature Specification
Image Acquisition Automatic
Image Processing Automatic
Image Reconstruction 3D
Cross-sectional Imaging Yes
Image Registration Automatic
Motion Compensation Automatic
Eye Tracking Software controlled
Image Enhancement Automatic
Noise Reduction Automatic
Artifact Detection Automatic
Repeatability Optimization Yes
Quality Score Automatic
Image Storage Digital
Examination Archive Integrated
Longitudinal Comparison Supported
Corneal Measurement Specifications
Measured Parameter Availability
Anterior Corneal Surface
Posterior Corneal Surface
Corneal Thickness
Central Corneal Thickness
Thinnest Corneal Thickness
Peripheral Thickness
Corneal Volume
Corneal Diameter
Corneal Apex
Corneal Vertex
Corneal Curvature
Simulated Keratometry
True Net Power
Total Corneal Refractive Power
Equivalent Keratometry Reading
Corneal Astigmatism
Irregular Astigmatism
Elevation Maps
Axial Curvature
Tangential Curvature
Refractive Power Maps
Best Fit Sphere Analysis
Best Fit Toric Ellipsoid

Reviews

There are no reviews yet.

Be the first to review “OCULUS Pentacam HR Corneal Tomographer”