ACOEM Falcon Vibration Analyzer
The ACOEM Falcon Vibration Analyzer is a portable industrial vibration analysis system designed for machinery condition monitoring and predictive maintenance. Featuring a wireless tri-axial sensor, Accurex™ automatic diagnostics, multi-channel measurement, built-in stroboscope, laser pyrometer, and advanced balancing capabilities,
Description
ACOEM Falcon Vibration Analyzer – Portable Vibration Analysis and Machine Condition Monitoring System
The ACOEM Falcon Vibration Analyzer is a portable industrial condition monitoring instrument designed to measure, analyze, and diagnose vibration problems in rotating machinery. Developed for maintenance professionals and reliability engineers, the Falcon combines advanced vibration measurement technology, wireless tri-axial sensing, automatic fault diagnostics, and in-field balancing capabilities in one integrated system.
Designed to support both routine machine inspections and advanced vibration analysis, the Falcon helps maintenance teams identify developing mechanical problems before they lead to unexpected equipment failures. Its intuitive touchscreen interface, wireless measurement sensor, built-in diagnostic functions, and connectivity options make it suitable for industrial plants, manufacturing facilities, power generation, and other demanding maintenance environments.
The system integrates ACOEM’s Accurex™ automatic diagnostic technology, which evaluates vibration measurements and provides machine condition assessments with recommended maintenance actions. Depending on the configuration, the Falcon can also support advanced analysis functions such as cross-channel phase measurements, run-up and coast-down analysis, Operating Deflection Shape (ODS), Frequency Response Function (FRF), and rotor balancing.
Key Features of the ACOEM Falcon Vibration Analyzer
1. Wireless Tri-Axial Vibration Measurement
The Falcon supports wireless vibration acquisition using a three-axis accelerometer. This sensor measures vibration in the horizontal, vertical, and axial directions, allowing technicians to collect multiple measurement directions without repeatedly repositioning a conventional single-axis sensor.
Wireless operation can improve inspection efficiency and operator safety, particularly when measuring machinery behind protective covers, inside restricted spaces, or in locations where cable connections are inconvenient.
2. Accurex Automatic Machine Diagnostics
Accurex™ is ACOEM’s integrated automatic diagnostic technology designed to help users interpret vibration measurement results. It evaluates machine vibration data and identifies potential mechanical problems, presenting detected faults with severity information, machine location, and diagnostic confidence.
3. Multi-Channel Vibration Analysis
The Falcon supports synchronous acquisition on up to four analog channels, depending on the instrument configuration, in addition to a trigger input. Multi-channel measurement allows users to compare vibration signals from different machine locations and perform advanced diagnostic procedures.
This capability is particularly useful for complex machinery, coupled equipment, and applications requiring phase or cross-channel analysis.
4. Built-In Stroboscope
The integrated stroboscope helps technicians determine rotating machine speed and observe rotating components. It supports speed measurement within its specified operating range and can assist with vibration analysis, balancing, and machine inspection procedures.
5. Integrated Laser Pyrometer
The built-in laser-sighting pyrometer provides non-contact temperature measurement. It enables technicians to inspect bearing housings and other machine surfaces without placing a contact temperature sensor directly on the equipment.
6. Built-In Camera and Machine Identification
The integrated camera allows users to capture photographs of machines, measurement locations, and visible defects. These images can help technicians identify assets, document inspection findings, and improve the clarity of maintenance reports.
7. Advanced Vibration Analysis Functions
Depending on the purchased software modules and hardware configuration, the Falcon can support:
- FFT spectrum analysis
- Time waveform analysis
- Envelope and demodulation analysis
- Overall vibration measurements
- Synchronous and phase analysis
- Orbit measurements
- Run-up and coast-down analysis
- Cross-channel analysis
- Frequency Response Function (FRF)
- Operating Deflection Shape (ODS)
- Single-plane and multi-plane balancing
ACOEM Falcon Vibration Analyzer Applications
Industrial Machinery Condition Monitoring
The Falcon can be used for routine vibration inspections of rotating equipment. Periodic measurements help maintenance teams identify changes in machine vibration patterns and monitor developing mechanical problems.
Electric Motor and Generator Analysis
Vibration measurements can support the evaluation of motors, generators, and related rotating equipment. Advanced analysis functions can help investigate imbalance, misalignment, looseness, and other vibration-related conditions.
Pump and Fan Vibration Monitoring
Pumps and fans are common applications for vibration-based maintenance. The Falcon can measure vibration at selected machine locations and help technicians investigate abnormal operating conditions.
Gearbox and Bearing Diagnostics
FFT spectrum, time waveform, and envelope analysis can help identify vibration patterns associated with bearing and gearbox problems. The diagnostic results can support maintenance planning and further inspection.
Rotor Balancing
With the appropriate balancing module, the Falcon can support field balancing operations. Its balancing functions help technicians evaluate vibration amplitude and phase while determining corrective weight adjustments.
Advanced Machinery Diagnostics
For more complex investigations, optional analysis capabilities such as cross-channel phase, ODS, FRF, and run-up or coast-down measurements can help engineers evaluate structural and dynamic machine behavior.
Technical Specifications
1. General Instrument Specifications
| Specification | Technical Details |
|---|---|
| Product Name | ACOEM Falcon |
| Product Category | Portable Vibration Analyzer |
| Manufacturer / Brand | ACOEM |
| Product Type | Portable vibration measurement, analysis, and condition monitoring instrument |
| Primary Function | Vibration data collection, machinery diagnostics, and balancing |
| Display Type | Graphic color touchscreen |
| Display Resolution | 800 × 480 pixels |
| Display Dimensions | 154 × 92 mm |
| Display Size | Approximately 7 inches |
| Brightness | Adjustable |
| Outdoor Visibility | Designed for use in direct sunlight |
| User Interface | Touchscreen with contextual function keys |
| Keyboard | On-screen QWERTY, AZERTY, and other available layouts |
| Operation | Single-hand measurement interface |
| Built-In Functions | Camera, pyrometer, stroboscope, QR-code reader, audio notes |
| Data Storage | 3.5 GB measurement memory in the referenced technical datasheet |
| Connectivity | USB, Ethernet, and Wi-Fi |
| Software Ecosystem | ACOEM NEST condition monitoring software |
| Measurement Modes | Route-based and off-route measurements |
| Typical Applications | Industrial rotating machinery and predictive maintenance |
2. Vibration Acquisition Specifications
| Specification | Technical Details |
|---|---|
| Acquisition Channels | Synchronous acquisition on 4 channels plus trigger input |
| Analog Input Channels | Up to 4, depending on instrument option |
| A/D Conversion | 24-bit |
| Sampling Frequency – Multi-Channel | 102.4 kHz per channel |
| Maximum Sampling Frequency | Up to 204.8 kHz on 1 channel |
| Real-Time Processing | Up to 40 kHz on 4 channels |
| Real-Time Processing – 2 Channels | Up to 80 kHz |
| Anti-Aliasing Filter | Integrated |
| Signal Processing | Digital signal processors |
| Wireless Sensor Support | FALCON WLS tri-axial accelerometer |
| Measurement Types | Acceleration, velocity, displacement, and other supported dynamic signals |
| Signal Integration | None, single integration, or double integration |
| Measurement Input | AC and DC analog inputs |
| Input Impedance | 100 kΩ AC/DC |
| AC Coupling | 0.3 Hz |
| AC Input Range | ±10 VAC |
| DC Input Range | -24 VDC to +24 VDC |
| IEPE Interface | Supported |
| IEPE Input Range | ±8 V |
| IEPE Constant Current | 4 mA |
| IEPE Supply Voltage | 23 VDC |
| Measurement Accuracy | ±1% (referenced analog input specification) |
| Overload Monitoring | Percentage indication with memorization |
| Sensor Compatibility | IEPE accelerometers and supported external transducers |
| Proximity Probe Support | Supported through appropriate input configuration and accessories |
3. Trigger Input Specifications
| Specification | Technical Details |
|---|---|
| Trigger Input | 1 dedicated trigger input |
| Input Range | ±10 V, 0 to +24 V, or 0 to -24 V |
| Input Impedance | 100 kΩ |
| Trigger Level | Adjustable |
| Trigger Configuration | Automatic setup function |
| Triggering Modes | Positive or negative slope |
| Trigger Delay | Programmable |
| Main Applications | RPM measurement, synchronous analysis, order analysis, and balancing |
| Tachometer Probe Supply | +5 VDC |
| Proximity Probe Supply | -24 VDC with compatible optional cable |
4. FFT Spectrum Analysis Specifications
| Specification | Technical Details |
|---|---|
| Analysis Type | Fast Fourier Transform (FFT) |
| Spectrum Resolution | 100 to 102,400 lines, depending on channel configuration |
| Maximum FFT Lines | 102,400 lines with up to 2 channels |
| Standard Resolution Options | 100, 200, 400, 800, 1,600, 3,200, 6,400, 12,800, 25,600, 51,200, and 102,400 |
| Frequency Ranges | 50 Hz to 80 kHz, depending on acquisition configuration |
| Published Frequency Range Options | 50, 100, 200, 500, 1,000, 2,000, 5,000, 10,000, 20,000, 40,000, and 80,000 Hz |
| Maximum Real-Time Processing | Up to 40 kHz |
| Averaging | 1 to 4,096 averages |
| Averaging Modes | Linear and peak hold |
| Overlap | 0%, 50%, and 75% |
| Weighting Windows | Rectangular, Hanning, and Flat-top |
| Amplitude Display | RMS, Peak, and Peak-to-Peak |
| Frequency Display | Hz and RPM |
| Scaling | Linear and logarithmic |
| Units | Engineering units and dB |
| Zoom | Up to 128× |
| Instantaneous Spectrum | Supported |
| Spectrum Averaging Display | Supported |
| Synchronous Spectrum Analysis | Supported |
5. Time Waveform Analysis Specifications
| Specification | Technical Details |
|---|---|
| Analysis Type | Time waveform analysis |
| Number of Samples | 256 to 65,536 samples |
| Standard Sample Options | 256, 512, 1,024, 2,048, 4,096, 8,192, 16,384, 32,768, and 65,536 |
| Extended Time Waveform | Up to 4,096K samples with the appropriate option |
| Maximum Long Time Wave | Up to 80 seconds, depending on channel allocation and configuration |
| Sampling Frequency | Selectable from 128 Hz to 204.8 kHz |
| Signal Types | Vibration, force, pressure, current, and supported user-defined signals |
| Signal Demodulation | Supported |
| Demodulation Filter | Programmable band-pass filter |
| Integration | None, single, or double |
| Triggering | Signal or external trigger input |
| Trigger Delay | Programmable |
| Trigger Slope | Positive or negative |
| Applications | Impact detection, transient analysis, and mechanical fault investigation |
6. Overall Vibration Measurement
| Specification | Technical Details |
|---|---|
| Measurement Parameter | Overall vibration level |
| Velocity Standards | ISO 2954, ISO 10816, and VDI 2056 |
| Reciprocating Machinery Standard | VDI 2063 |
| Detection Modes | RMS, true peak, equivalent peak, and peak-to-peak |
| High-Pass Filters | 2 Hz, 10 Hz, and 3,000 Hz |
| Low-Pass Filters | 300 Hz, 1,000 Hz, 2,000 Hz, 3,000 Hz, 20,000 Hz, and 40,000 Hz |
| Frequency Band Measurement | Overall level in selected frequency bands |
| Alarm Types | Up to 4 alarm types |
| Alarm Levels | Up to 4 levels |
| Measurement Duration | Programmable from 1 to 99 seconds |
| Alarm Comparison | Comparison with previous measurements |
| Display | Instantaneous value, measured value, alarm limits, and previous measurement |
| Integration | Acceleration, velocity, or displacement calculation |
| Data Presentation | Engineering units and dB |
7. Bearing and Envelope Analysis
| Specification | Technical Details |
|---|---|
| Bearing Analysis | Rolling-element bearing condition assessment |
| Bearing Diagnostic Parameter | Defect Factor™ |
| Defect Factor Scale | 0 to 12 for standard rotation speed, as described in the referenced datasheet |
| Envelope Analysis | Supported |
| Signal Processing | Demodulated time waveform |
| Band-Pass Filtering | Programmable |
| Filter Center Frequency | User-selectable |
| Filter Bandwidth | Selectable from 1/2 to 1/128 of the analysis range |
| Kurtosis Measurement | Supported |
| Shock Detection | Supported for low-speed rolling-element bearing applications |
| Diagnostic Purpose | Detection of bearing-related impacts and high-frequency vibration patterns |
8. Vector, Phase, and Synchronous Analysis
| Specification | Technical Details |
|---|---|
| Vector Measurement | Supported |
| Phase Spectrum | Supported |
| Synchronous Averaging | 1 to 4,096 averages |
| Vector Spectrum Lines | 100 to 6,400 |
| Vector Frequency Ranges | 50 Hz to 40 kHz, depending on configuration |
| Trigger Source | Signal or external trigger input |
| Trigger Delay | Programmable |
| Phase Analysis | Available through supported measurement functions and options |
| Cross-Channel Analysis | Available with the appropriate module |
| Orbit Display | Supported using two-channel measurement |
| Main Applications | Imbalance, alignment investigation, and dynamic machine analysis |
9. Rotation Speed and Stroboscope Specifications
| Specification | Technical Details |
|---|---|
| Speed Measurement Method | External trigger input and built-in stroboscope |
| Trigger-Based Speed Range | 12 to 288,000 RPM |
| Trigger Frequency Range | 0.2 to 4,800 Hz |
| Built-In Stroboscope | Yes |
| Stroboscope Speed Range | 30 to 15,000 RPM |
| Automatic Speed Setup | Supported |
| Speed Adjustment | 1/2×, 2×, fast, and fine adjustment |
| Flash Duration | Adjustable from 0.5° to 15° |
| Measurement Applications | Rotational speed verification and balancing |
| Trigger Synchronization | Supported |
10. Built-In Pyrometer Specifications
| Specification | Technical Details |
|---|---|
| Measurement Type | Non-contact infrared temperature measurement |
| Temperature Sensor | Built-in laser-sighting pyrometer |
| Temperature Range | 0°C to 200°C |
| Accuracy | ±3°C at ambient temperatures from 18°C to 28°C |
| Resolution | 0.5°C |
| Repeatability | ±1°C |
| Field of View | 5° at 50% |
| Target Size | Approximately 4 cm at 50 cm distance |
| Response Time | 1 second |
| Emissivity | Fixed at 0.95 |
| Measurement Method | Contactless |
| Typical Applications | Bearing housings and machine surface temperature checks |
11. Camera and Asset Identification Specifications
| Specification | Technical Details |
|---|---|
| Built-In Camera | Yes |
| Camera Resolution | 640 × 480 pixels |
| Focus | Autofocus |
| Focus Distance | 20 cm to infinity |
| Flash | Supported |
| Image Applications | Machine identification and inspection documentation |
| QR-Code Reader | Built-in |
| QR-Code Reading Distance | Approximately 20 to 50 cm, depending on code size |
| Identification Function | Measurement-point identification |
| Learning Mode | Supported |
| Inspection Notes | Text and audio comments supported |
12. Communication and Data Management
| Specification | Technical Details |
|---|---|
| USB Interface | USB 2.0 Type B device |
| USB Host | USB 2.0 Type A |
| Ethernet | Supported |
| Wi-Fi | Supported |
| Wireless Sensor Communication | Wireless connection with compatible tri-axial sensor |
| PC Connection | Direct USB and network communication |
| Data Transfer | USB, Ethernet, and Wi-Fi |
| Route Management | Route upload and download |
| Remote Route Exchange | Email-based exchange supported |
| Cloud Connectivity | Supported through compatible ACOEM platform services |
| Analysis Software | ACOEM NEST |
| Reporting | Measurement reports and inspection documentation |
| Measurement Storage | 3.5 GB in the referenced technical datasheet |
13. Battery and Power Specifications
| Specification | Technical Details |
|---|---|
| Battery Type | High-density rechargeable lithium-ion |
| Battery Design | Removable battery |
| Charging | Rechargeable without removing the battery |
| Battery Life | Approximately 10 hours under intensive use |
| Battery Monitoring | Automatic battery test and calibration function |
| Power Management | Programmable standby and automatic shutdown |
| Power Supply | External rechargeable power supply |
| Operating Mode | Portable handheld operation |
14. Mechanical and Environmental Specifications
| Specification | Technical Details |
|---|---|
| Protection Rating | IP65 |
| Housing | Industrial handheld enclosure |
| Protective Design | Shock-protection rubber casing |
| Drop Resistance | 1.2 meters for standard version |
| EX Version Drop Resistance | 1 meter, according to referenced datasheet |
| Dimensions | 200 × 265 × 65 mm |
| Weight | Approximately 1.8 kg, including battery and rubber protection |
| Operating Temperature | -10°C to +55°C |
| Relative Humidity | Up to 95%, non-condensing |
| Display Protection | Protective accessories available |
| Intended Environment | Industrial maintenance and inspection environments |
15. Falcon-EX Hazardous Area Specifications
| Specification | Technical Details |
|---|---|
| Version | FALCON-EX |
| Protection Type | Intrinsically safe version |
| ATEX Certification | EX II 3 G |
| ATEX Protection Marking | Ex ic IIC T4 Gc |
| IECEx Certification | Ex ic IIC T4 Gc |
| Application | Approved hazardous gas environments within certification limits |
| Accessories | Certified accessories required |
| Drop Resistance | 1 meter, according to referenced datasheet |
| Important Note | Confirm the exact instrument certification and approved accessories before use in a hazardous area |
16. Software and Optional Analysis Modules
| Function / Module | Description |
|---|---|
| Data Collector | Routine vibration route collection |
| Off-Route Measurement | Additional measurements outside predefined routes |
| Accurex™ Automatic Diagnosis | Automated vibration-based machine diagnostics |
| Camera Activation | Machine and inspection image documentation |
| Two Analog Channel Option | Additional analog measurement capability |
| Four Analog Channel Extension | Expanded multi-channel acquisition |
| Expert Measurement Option | Extended spectrum and waveform capabilities |
| Balancing Module | Field balancing operations |
| Run-Up / Coast-Down Module | Dynamic analysis during acceleration and deceleration |
| Cross-Channel Analysis | Comparison of signals from multiple channels |
| Phase Analysis | Phase relationship measurement |
| FRF | Frequency Response Function analysis |
| ODS | Operating Deflection Shape analysis |
| NEST Software | Data management, analysis, and reporting environment |
17. Available Falcon Package Configurations
The Falcon platform can be supplied with different software and hardware configurations. The exact package names and included functions should be confirmed with the supplier.
| Configuration / Package | Typical Capabilities |
|---|---|
| Essential | Falcon hardware and basic data collection functions |
| Smart | Data collection with additional diagnostic and camera-related functions, depending on package |
| Expert | Expanded measurement capabilities and additional analog channel options |
| Ultimate | Advanced analysis and balancing capabilities, depending on purchased modules |
| Optional Modules | Off-route, Accurex, balancing, run-up/coast-down, FRF, ODS, and cross-channel analysis |




There are no reviews yet.