JEISYS Tri-Beam Advanced Pigmentation Laser
The JEISYS Tri-Beam Advanced Pigmentation Laser combines Q-Switched Nd:YAG technology, Top-Hat beam delivery, and multi-wavelength capabilities for advanced pigment correction, tattoo removal, and skin revitalization treatments.
Description
JEISYS Tri-Beam Advanced Pigmentation Laser: Multi-Wavelength Q-Switched Nd:YAG Platform for Pigment Correction and Skin Rejuvenation
The JEISYS Tri-Beam Advanced Pigmentation Laser is a high-performance Q-Switched Nd:YAG laser platform engineered for pigmentation treatment, tattoo removal, skin revitalization, melasma management, and laser toning procedures. Developed by JEISYS Medical, Tri-Beam combines multiple wavelengths, advanced pulse delivery technology, and homogeneous beam profiles to provide safe and effective treatment for a wide range of dermatological and aesthetic indications.
Designed for dermatologists, aesthetic physicians, laser specialists, and skin clinics, the Tri-Beam system delivers high peak power with precise energy distribution, helping practitioners achieve consistent clinical outcomes while minimizing unwanted thermal injury.
What Is the JEISYS Tri-Beam Laser?
Advanced Q-Switched Laser Technology
Tri-Beam is a multi-functional Q-Switched Nd:YAG laser that utilizes ultra-short nanosecond pulses to target unwanted pigmentation and tattoo ink through selective photothermolysis.
Core Treatment Capabilities
- Pigmented lesion removal
- Melasma management
- Tattoo removal
- Skin toning
- Acne treatment
- Pore refinement
- Skin rejuvenation
- Dermal pigmentation correction
Technology
Rich-PTP, which stands for Photoacoustic Therapy Pulse is a unique and completely exclusive feature of TRI-BEAM. It has achieved unmatched success in clinical efficacy compared to other Q-Switch Nd:YAG lasers. Rich-PTP™ specifically shatters targeted chromophores and maximises photo-acoustic effect resulting in a faster, safer and more effective toning of the treatment area and superior aesthetic results thanks to this extremely powerful and advanced energy. So powerful, the Rich-PTP™ technology delivers 2-pulse energy and up to 20Hz of power in a much shorter time, which minimises damage to the epidermal cells while selectively targeting and destroying pigmented lesions.
In addition to a 1060nm capability for removing dark ink and a 532nm capability for red and orange ink, the TRI-BEAM™ also has 585nm and 650nm dye wavelength handpieces available. The 585nm wavelength handpiece treats sky blue ink, while the 650nm wavelength handpiece targets green ink, allowing for effective full-colour tattoo removal.
TRI-BEAM is also available with an additional fractional handpiece. The fractional handpiece assists in the delivery of exceptional treatment outcomes, while at the same time reducing the possibility of post-inflammatory hyperpigmentation complications associated with less sophisticated tattoo removal devices.
Why Choose JEISYS Tri-Beam?
Modern aesthetic clinics require a laser system capable of treating:
Pigmentation Disorders
- Melasma
- Freckles
- Lentigines
- Age spots
- Café-au-lait macules
- Post-inflammatory hyperpigmentation
Tattoo Removal
- Black tattoos
- Blue tattoos
- Red tattoos
- Multicolor tattoos
Skin Rejuvenation
- Uneven skin tone
- Enlarged pores
- Dull skin
- Fine wrinkles
- Texture irregularities
Key Features
Triple Wavelength Technology
The Tri-Beam platform incorporates multiple wavelengths to maximize treatment versatility.
1064 nm Nd:YAG
Ideal for:
- Deep dermal pigmentation
- Melasma
- Nevus of Ota
- Black tattoos
- Blue tattoos
- Skin toning
532 nm Nd:YAG
Suitable for:
- Superficial pigmentation
- Solar lentigines
- Freckles
- Red tattoo pigments
- Orange tattoo pigments
Top-Hat Beam Profile Technology
Unlike conventional Gaussian beam lasers, Tri-Beam utilizes a homogeneous beam profile.
Benefits
- Uniform energy distribution
- Reduced hot spots
- Increased treatment safety
- Improved patient comfort
- More predictable outcomes
Ultra-Short Nanosecond Pulse Duration
Q-Switched technology delivers energy in nanoseconds.
Advantages
- Effective pigment fragmentation
- Reduced collateral tissue damage
- Faster pigment clearance
- Minimal epidermal injury
High Peak Power Output
The system generates powerful photoacoustic effects that efficiently break down pigment particles.
Clinical Benefits
- Better tattoo clearance
- Improved melasma protocols
- Enhanced skin brightening treatments
- Reduced treatment sessions
Advanced Laser Toning Mode
Laser toning protocols are commonly used for:
- Skin brightening
- Melasma management
- Pore reduction
- Sebum control
- Overall skin revitalization
Tattoo Removal
The system effectively targets multiple tattoo colors.
Tattoo Color Guide
| Tattoo Color | Recommended Wavelength |
|---|---|
| Black | 1064 nm |
| Dark Blue | 1064 nm |
| Brown | 532 nm |
| Red | 532 nm |
| Orange | 532 nm |
| Purple | Dye Handpiece |
| Resistant Colors | Specialized Wavelengths |
Specifications
| Category | Specification |
|---|---|
| Product Name | JEISYS Tri-Beam Advanced Pigmentation Laser |
| Manufacturer | JEISYS Medical Inc. |
| Technology | Q-Switched Nd:YAG Laser |
| Laser Type | Multi-Wavelength Pigmentation Laser |
| Primary Wavelength | 1064 nm |
| Secondary Wavelength | 532 nm |
| Optional Dye Wavelengths | Available |
| Laser Medium | Nd:YAG Crystal |
| Pulse Duration | Nanosecond Range |
| Treatment Modes | Q-Switched, Laser Toning |
| Beam Profile | Top-Hat Homogeneous Beam |
| Energy Delivery | Uniform Energy Distribution |
| Peak Power | High Peak Output |
| Spot Size Range | Adjustable |
| Repetition Rate | Adjustable |
| Tattoo Removal Capability | Yes |
| Melasma Treatment | Yes |
| Freckle Removal | Yes |
| Lentigo Treatment | Yes |
| Nevus of Ota Treatment | Yes |
| Skin Rejuvenation | Yes |
| Laser Toning | Yes |
| Acne Treatment | Yes |
| Sebum Control | Yes |
| Pore Reduction | Yes |
| User Interface | Full Color Touchscreen |
| Treatment Presets | Available |
| Custom Settings | Supported |
| Energy Calibration | Automatic |
| Aiming Beam | Integrated Red Diode |
| Cooling Compatibility | External Cooling Systems Compatible |
| Clinical Database | Available |
| Treatment Records | Available |
| Software Upgrades | Supported |
| Safety Monitoring | Integrated |
| Electrical Requirements | 100–240 VAC |
| Frequency | 50/60 Hz |
| Platform Type | Mobile Cart-Based System |
| Regulatory Status | Region Dependent |
| Intended Users | Dermatologists & Aesthetic Physicians |
| Installation Environment | Medical Clinics & Hospitals |
| Maintenance Schedule | Manufacturer Recommended |
| Clinical Applications | Pigmentation, Tattoos, Rejuvenation |
| Patient Skin Types | Multiple Fitzpatrick Types |
| Downtime | Minimal |
| Treatment Speed | High-Efficiency Workflow |












There are no reviews yet.